CSI Division

CSI Division 32 Exterior Improvements: section numbers and submittal deviations

What gets flagged between a Division 32 Exterior Improvements spec section and the submittal package, why it matters, and how each deviation is graded, so you can catch it before you send the package or before you approve it.

Short answer

Exterior Improvements is Division 32 in CSI MasterFormat, so its section numbers start with 32. Common sections include 32 11 00 Base Courses, 32 12 00 Flexible Paving, and 32 13 00 Rigid Paving. Its submittals deviate most often on product substitutions, performance ratings, and missing certifications.

Division 32 covers exterior site improvements: paving, landscaping, irrigation, site furnishings, fencing, and athletic surfaces. Common CSI sections submitted for review:

Division 32 Exterior Improvements CSI section numbers

Division 32 Exterior Improvements spec sections frequently submitted for review:

Representative Division 32 CSI MasterFormat sections
SectionTitle
32 01 00Operation and Maintenance of Exterior Improvements
32 11 00Base Courses (aggregate base, crushed stone)
32 12 00Flexible Paving (hot mix asphalt, HMA)
32 13 00Rigid Paving (portland cement concrete)
32 14 00Unit Paving (brick, concrete pavers, flagstone)
32 16 00Curbs and Gutters
32 17 00Pavement Markings
32 18 00Athletic and Recreational Surfacing (rubberized track, synthetic turf)
32 31 00Fences and Gates (chain link, ornamental metal, wood)
32 32 00Retaining Walls (segmental block, gabion)
32 84 00Planting Irrigation
32 90 00Planting
32 91 00Soil Preparation
32 93 00Plants
32 94 00Planting Accessories

Sending a Division 32 package? Run the free Division 32 pre-submittal checklist first. It prints or downloads as a PDF, no email required.

The six deviation categories in Division 32 Exterior Improvements

Every issue Deviation Check flags maps to one of six categories. Here is how each appears in Division 32 Exterior Improvements submittals, with the full guide one click away.

Manufacturer or Product Substitution

Blocker The submittal proposes a different manufacturer or product than the spec names, without an approved or-equal or substitution request.

Site improvement specs frequently name brand products or approved manufacturers. Look for:

Manufacturer or Product Substitution in Division 32 Exterior Improvements submittals →

Performance Specification Gap

Blocker A measurable performance property in the submittal (rating, capacity, tolerance, efficiency) does not meet what the spec requires.

Key performance parameters in exterior improvement submittals:

Performance Specification Gap in Division 32 Exterior Improvements submittals →

Missing Certification or Compliance Documentation

Fix and Resubmit A required listing, test report, certification, or compliance document is absent from the submittal package.

Required certifications in exterior improvement submittals:

Missing Certification or Compliance Documentation in Division 32 Exterior Improvements submittals →

Aesthetic Deviation

Fix and Resubmit A visible attribute (color, finish, texture, profile) differs from the spec or the architect-approved sample.

Common in exterior improvements - highly visible to owners and public:

Aesthetic Deviation in Division 32 Exterior Improvements submittals →

Detail or Installation Mismatch

Fix and Resubmit The submitted detail, dimension, anchorage, or installation method differs from what the spec or drawings require.

Detail or Installation Mismatch in Division 32 Exterior Improvements submittals →

Submittal Package Incompleteness

Fix and Resubmit A required submittal element (cut sheet, schedule, calculation, sample) is missing, leaving the package unreviewable as submitted.

Commonly required items in Div 32 specs:

Submittal Package Incompleteness in Division 32 Exterior Improvements submittals →

How Division 32 deviations are graded

Each finding is graded Blocker, Fix and Resubmit, or Note. Division 32 escalation rules:

  • Asphalt binder grade (PG) lower than climate zone and traffic requirement: Always BLOCKER (premature rutting or thermal cracking - pavement will fail prematurely)
  • Concrete paving f'c below spec: BLOCKER (structural adequacy of parking/drive surface)
  • Concrete air content below ACI 301 minimum for freeze-thaw exposure: BLOCKER in cold climates (scaling and spalling failure)
  • Athletic surface Gmax above 200g per ASTM F355: Always BLOCKER (user safety - head impact injury threshold)
  • Missing stormwater authority approval where impervious area threshold is crossed: BLOCKER (regulatory - cannot pave without permit)
  • Plant caliper below specified ANSI Z60.1 size: FIX_AND_RESUBMIT (contractual requirement; owner paid for specified size)
  • Unapproved plant species substitution: FIX_AND_RESUBMIT (owner decision required; not a contractor unilateral call)
  • Asphalt air voids outside 3-5% target range in mix design: FIX_AND_RESUBMIT (durability impact but not immediate structural failure)
  • Irrigation DU below 0.70 for turf zones: FIX_AND_RESUBMIT (water waste and uneven coverage; increasingly regulated by water districts)
  • Missing synthetic turf third-party test report: FIX_AND_RESUBMIT (manufacturer data alone does not satisfy spec)
  • Pavement section thickness below geotech recommendation: BLOCKER (premature structural failure)
  • Fencing post embedment depth below spec: FIX_AND_RESUBMIT unless in high-wind/security zone, then BLOCKER
  • Missing asphalt mix design from certified lab: FIX_AND_RESUBMIT (cannot verify conformance without it)

Run a Division 32 submittal review

Upload a Division 32 spec section and your submittal package before you send it, and get a one-page deviation report in under five minutes, so the package goes through the first time. GC reviewers use it the same way on a package that just arrived. Before that, work through the free Division 32 checklist.

Frequently asked questions

What is the CSI code for exterior improvements?

Exterior Improvements is CSI MasterFormat Division 32, and every section number in it starts with 32. Common sections include 32 11 00 Base Courses, 32 12 00 Flexible Paving, 32 13 00 Rigid Paving, 32 14 00 Unit Paving, and 32 16 00 Curbs and Gutters. Type any number into the CSI division lookup to decode it.

What is Division 32 Exterior Improvements in construction?

Division 32 covers exterior site improvements: paving, landscaping, irrigation, site furnishings, fencing, and athletic surfaces. In a CSI MasterFormat spec, its sections carry the submittal and product requirements a Division 32 package is reviewed against.

What are the most common deviations in Division 32 Exterior Improvements submittals?

The most common are product or manufacturer substitutions, performance specification gaps, and missing certification or compliance documentation. Deviation Check sorts every finding into one of six categories.

How are Division 32 deviations graded?

Each finding is graded Blocker (resolve before approval), Fix and Resubmit (correct and re-send before fabrication or install), or Note (acceptable with a comment).

View this page as Markdown for LLMs and note-taking.