CSI Division

CSI Division 22 Plumbing: section numbers and submittal deviations

What gets flagged between a Division 22 Plumbing spec section and the submittal package, why it matters, and how each deviation is graded, so you can catch it before you send the package or before you approve it.

Short answer

Plumbing is Division 22 in CSI MasterFormat, so its section numbers start with 22. Common sections include 22 11 13 Facility Water Distribution Piping, 22 11 16 Domestic Water Piping, and 22 13 16 Sanitary Waste and Vent Piping. Its submittals deviate most often on product substitutions, performance ratings, and missing certifications.

Division 22 covers plumbing systems in commercial construction: domestic water piping, sanitary waste and vent piping, storm drainage, plumbing fixtures, water heaters, and plumbing specialties. Common CSI sections submitted for review:

Division 22 Plumbing CSI section numbers

Division 22 Plumbing spec sections frequently submitted for review:

Representative Division 22 CSI MasterFormat sections
SectionTitle
22 05 00Common Work Results for Plumbing
22 05 19Meters and Gages for Plumbing Piping
22 05 23General-Duty Valves for Plumbing Piping
22 05 29Hangers and Supports for Plumbing Piping and Equipment
22 05 53Identification for Plumbing Piping and Equipment
22 07 00Plumbing Insulation
22 11 13Facility Water Distribution Piping
22 11 16Domestic Water Piping
22 13 16Sanitary Waste and Vent Piping
22 13 19Sanitary Waste Piping Specialties (cleanouts, floor drains, interceptors)
22 14 13Facility Storm Drainage Piping
22 33 00Electric Domestic Water Heaters
22 34 00Fuel-Fired Domestic Water Heaters
22 35 00Domestic Water Heat Exchangers
22 40 00Plumbing Fixtures
22 42 13Commercial Water Closets (toilets)
22 42 16Commercial Urinals
22 42 39Commercial Faucets
22 42 43Commercial Sinks
22 47 00Drinking Fountains and Water Coolers

Sending a Division 22 package? Run the free Division 22 pre-submittal checklist first. It prints or downloads as a PDF, no email required.

The six deviation categories in Division 22 Plumbing

Every issue Deviation Check flags maps to one of six categories. Here is how each appears in Division 22 Plumbing submittals, with the full guide one click away.

Manufacturer or Product Substitution

Blocker The submittal proposes a different manufacturer or product than the spec names, without an approved or-equal or substitution request.

Plumbing specs name specific pipe, fixture, and equipment manufacturers. Look for:

Manufacturer or Product Substitution in Division 22 Plumbing submittals →

Performance Specification Gap

Blocker A measurable performance property in the submittal (rating, capacity, tolerance, efficiency) does not meet what the spec requires.

Key performance parameters in plumbing submittals:

Performance Specification Gap in Division 22 Plumbing submittals →

Missing Certification or Compliance Documentation

Fix and Resubmit A required listing, test report, certification, or compliance document is absent from the submittal package.

Required certifications in plumbing submittals:

Missing Certification or Compliance Documentation in Division 22 Plumbing submittals →

Aesthetic Deviation

Fix and Resubmit A visible attribute (color, finish, texture, profile) differs from the spec or the architect-approved sample.

Aesthetic Deviation in Division 22 Plumbing submittals →

Detail or Installation Mismatch

Fix and Resubmit The submitted detail, dimension, anchorage, or installation method differs from what the spec or drawings require.

Detail or Installation Mismatch in Division 22 Plumbing submittals →

Submittal Package Incompleteness

Fix and Resubmit A required submittal element (cut sheet, schedule, calculation, sample) is missing, leaving the package unreviewable as submitted.

Commonly required items in Div 22 specs:

Submittal Package Incompleteness in Division 22 Plumbing submittals →

How Division 22 deviations are graded

Each finding is graded Blocker, Fix and Resubmit, or Note. Division 22 escalation rules:

  • Pipe material below spec pressure rating: BLOCKER (burst risk, property damage, injury)
  • Missing NSF/ANSI 61 for potable water components: BLOCKER (health code, Safe Drinking Water Act)
  • Lead-free non-compliance (NSF 372): BLOCKER (Federal law, Safe Drinking Water Act 2014)
  • Water heater capacity below design load: BLOCKER (will not meet demand)
  • Backflow preventer grade below code/hazard requirement: BLOCKER (cross-contamination, health risk)
  • Fixture water consumption exceeding code maximum: BLOCKER (plumbing code violation)
  • Missing ADA compliance for accessible fixtures: BLOCKER (ADA/ANSI A117.1 requirement)
  • Missing seismic anchorage for water heaters where required: BLOCKER (IBC, California Health & Safety Code)
  • Missing scald protection (ASSE 1016/1017) where spec requires: BLOCKER (injury risk)
  • Pipe material mismatch (lower grade): BLOCKER if pressure-rated service, FIX_AND_RESUBMIT if gravity drain
  • Fixture color mismatch: FIX_AND_RESUBMIT (aesthetic)
  • Missing WaterSense certification where spec requires: FIX_AND_RESUBMIT (LEED/code compliance)
  • Insulation thickness below ASHRAE 90.1 minimum: FIX_AND_RESUBMIT (energy code)

Run a Division 22 submittal review

Upload a Division 22 spec section and your submittal package before you send it, and get a one-page deviation report in under five minutes, so the package goes through the first time. GC reviewers use it the same way on a package that just arrived. Before that, work through the free Division 22 checklist.

Frequently asked questions

What is the CSI code for plumbing?

Plumbing is CSI MasterFormat Division 22, and every section number in it starts with 22. Common sections include 22 11 13 Facility Water Distribution Piping, 22 11 16 Domestic Water Piping, 22 13 16 Sanitary Waste and Vent Piping, 22 13 19 Sanitary Waste Piping Specialties, and 22 14 13 Facility Storm Drainage Piping. Type any number into the CSI division lookup to decode it.

What is Division 22 Plumbing in construction?

Division 22 covers plumbing systems in commercial construction: domestic water piping, sanitary waste and vent piping, storm drainage, plumbing fixtures, water heaters, and plumbing specialties. In a CSI MasterFormat spec, its sections carry the submittal and product requirements a Division 22 package is reviewed against.

What are the most common deviations in Division 22 Plumbing submittals?

The most common are product or manufacturer substitutions, performance specification gaps, and missing certification or compliance documentation. Deviation Check sorts every finding into one of six categories.

How are Division 22 deviations graded?

Each finding is graded Blocker (resolve before approval), Fix and Resubmit (correct and re-send before fabrication or install), or Note (acceptable with a comment).

View this page as Markdown for LLMs and note-taking.